Description

The Protege XST split tube furnaces have a compact, lightweight, space saving design. This model is an excellent choice to begin thermal processing in a laboratory environment. The hinged body which is split along its length allows for easy process tube changes and simple installation of process tubes with end seals attached. The Protrgr has Fibercraft™ vacuum formed ceramic fiber heating elements with free radiating wire embedded into the body of the heater and tube adapters integrated into the ends. Excellent temperature uniformity and a programmable control system make the Protege a valuable addition to any lab.

  • 1100°C maximum operating temperature
  • Vacuum formed ceramic fiber heating elements ensure rapid heat up, excellent temperature uniformity and quick cool down
  • Compact, lightweight design
  • Safety switch disconnects power toheating elements when opened
  • Choice of Integrated Eurotherm 3216CP (8 segments) or 2416CP (24 segments) PID control systems
  • Long life Inconel sheathed Type K thermocouple
  • Accepts process tube outer diameters up to 1.25" (31mm)
  • Heated length 12" (304mm)
  • Furnace and controller ship fully assembled and ready for connection to incoming power supply
  • Can be used in horizontal or vertical orientation
Loading options...

Description

These XSL solid tube furnaces will accept a process tube up to 2.75" (70 mm) and have a maximum operating temperature of 1200°C (2192°F). They have an interconnected control system and the furnace can be operated horizontally or vertically. The XSL solid tube furnaces have a continuous solid body design. Process tubes can be inserted through the furnace chamber before attaching end seals. These furnaces use ceramic refractory heating elements with embedded resistance wire. The tube adapters can be changed by removing the end caps so that multiple process tube sizes can be used with one furnace. Temperature uniformity is excellent due to the heavy ceramic refractory heating elements and continuous solid tube heated chamber. These furnaces ship two weeks after receipt of order.

  • 1200°C maximum operating temperature
  • Ceramic refractory with embedded wire heating elements ensure excellent temperature uniformity
  • Thermcraft SmartControl touch screen PID control system
  • Accepts process tube outer diameters up to 2.75" (69mm)
  • Heated lengths up to 24" (609mm)
  • Includes 1 set of tube adapters sized to desired internal diameter
  • 10' (3m) interconnecting and power cables
  • Furnace and controller ship fully assembled and ready for connection to incoming power supply
  • Can be used in horizontal or vertical orientation
Loading options...

Description

These XST split tube furnaces will accept process tubes up to 6" (152 mm) and have a maximum operating temperature of 1200°C (2192°F). They have an interconnected control system and the furnace can be operated horizontally or vertically. The XST split tube furnaces have a hinged body which is split along its length. This design allows for easy process tube changes and simple installation of process tubes with end seals attached. These furnaces use Fibercraft™ vacuum formed ceramic fiber heating elements with free radiating wire embedded into the body of the heater. The tube adapters are removable and interchangeable so that multiple process tube sizes can be used with one furnace. Single zone models have excellent temperature uniformity and the three zone models can extend the uniform flat zone by independently controlling the end zones.

Ships two weeks after ordering!

SmartControl Standard Controller

The SmartControl System combines all of the features of typical PID controllers, video/chart recorders and data logging systems into a single, intuitive device. The SmartControl provides a 4.3" color touch screen interface with standard, user configurable, runtime features for 1-3 zone control applications. All loop configuration and runtime user access is configurable at the device with no PC software required. SmartControl supports 1-3 control zones, offering up to 4 control outputs per zone, powerful profiling capabilities including up to three event outputs and more.

Integrated LAN features include e-mail, SMS (text messaging) on alarm, FTP (file transfer protocol for automated file transfer/data backup), remote access (web and VNC embedded servers) and national timeserver time synchronization are standard. The web and VNC servers allow remote access using a PC, tablet or other smart phone devices.

If you can use a "smart device" (iPhone, Android, etc.), you can use SmartControl!
User configurable with "slide nav" finger navigation similar to "smart devices" or with a traditional drop down menu system, SmartControl is intuitive to operate and use. With one touch language configuration for all icons, menus and help screens, SmartControl provides ease of use in any one of 28 languages.

  • 1200°C maximum operating temperature
  • Vacuum formed ceramic fiber heating elements ensure rapid heat up, excellent temperature uniformity and quick cool down
  • Thermcraft SmartControl touch screen PID control system
  • Accepts process tube outer diameters up to 6" (152mm)
  • Heated lengths up to 36" (609mm)
  • Includes 1 set of tube adapters sized to desired internal diameter
  • 10' (3m) interconnecting and power cables
  • Furnace and controller ship fully assembled and ready for connection to incoming power supply
  • Can be used in horizontal or vertical orientation (vertical mounting brackets included)
Loading options...